Specifications

Main
product range PowerLogic P5
product function Protection and relay control
use of relay Universal
Product reference P5M30-CEDE-IAAAH-BAFK
circuit breaker type 30TE
mounting the device Recessed
mounting bracket Rack
installation mode Extractable product
Food 48…230 V AC/DC
Measuring inputs 3 TC 1/5 A for phase current
1 TC 1/5 A for residual current
4 TP 101 V/110 V for voltage
31 digital
number of sensors 0 temperature sensor(s)
0 arc flash sensor(s)
Number of digital inputs (DI) 16
number of analogue inputs 0
Number of digital outputs (DO) 1 guard dog
8 guard dog
Number of analog outputs 0
Communication ports Front USB port with 1 connector
Rear RJ45 with 2 connectors with backup memory
Communication protocols IEC 61850 ed. 1
IEC 61850 ed. 2
IEC 60870-5-101
DNP3 TCP
Modbus TCP
Ethernet IP
communication port protocol RSTP
PTP
Cybersecurity Communication port hardening
Firmware signature
Client IP address filter
Secure communication with associated tools
Security policy management
Role-based access control LDAP
security log RADIUS-based user authentication IEC 62443-4-2 SL1
 
Protective functions Phase overcurrent 50/51
Directional phase overcurrent 67
Earth fault 50N/51N
Directional earth fault 67N
Transient intermittent 67NI
Capacitor step unbalance 51C
Broken conductor 46 I2/I1
Selective overcurrent logic 46 I2/I1
Trip on fault (SOTF)
Circuit breaker failure 50BF
Directional active underpower 37P
Fault location 21FL
Recloser 79
Phase undercurrent 37
Long start, locked rotor 48/51LR
Motor restart inhibition 66
Capacitor overvoltage 59C
Negative sequence overcurrent 46
Overvoltage 59
Undervoltage 27
Positive sequence undervoltage 27P
Residual overvoltage 59N
Underfrequency 81/81N
Frequency derivative 81R
Synchronism check 25
Interlock 86
Supervision TC 60
Supervision TP 60
H2 detection 68H2
H5 detection 68H5
Negative sequence overcurrent 47
Programmable thresholds 99
Programmable curve
communication port protocol No
Measuring functions Three-phase
current Zero sequence
current Positive component
current Negative component current Negative component
current Ratio current between negative sequence and direct
Phase-to-earth
voltage Phase-to-phase voltage
Zero sequence
voltage Positive component
voltage Negative component voltage Negative component
voltage Ratio voltage between negative sequence and direct
Short-circuit fault reactance Negative component fault
current location Phase synoptic fault
reactance Earth fault reactance
Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Phase synoptic voltage Phase synoptic current Current 2nd, 15th harmonics with TDH Voltage 2nd, 15th harmonics with TDH Voltage interruption Monitoring of the status of the cut-off devices
 
Control functions Circuit breaker control and monitoring
Programmable interlock
Local control on vector diagram
Local control with I/O keys
Direct control/remote control
2 function keys
Mobile application with EcoStruxureTM Power Device application
Web server
Programmable logic
Controllable devices 4 ordered + 8 displayed
Number of setting groups 4
Monitoring functions Trip circuit supervision 74
Circuit breaker supervision
Relay self-supervision
Registers and records Event recording
Recording of oscilloscopes
Triggering context
Type of diagnostic cut-off organ TC/TP 60 supervision
TC supervision
TCS tripping circuit supervision
connection mode Removable screw (logic input/output)
Removable ring terminals (current transformer)
Removable pin (voltage transformer)
Ring terminals (voltage transformer)
Complementary
operating threshold 24…230 V AC/DC                                                                                         
time synchronization protocol SNTP
software name EcoStruxure Power Device: virtual injection test
ESetup Easergy Pro
web server Built-in HTTP server
display type LCD 128 x 64 pixels with single-line synoptic
number of keys 2 customizable
local signaling 10 x 4 programmable 3-color LEDs
4 x 8 programmable red LEDs
standards IEC
height 169.5 mm
width 170 mm
depth 205 mm
product mass 2.5 kg maximum