Specifications
Using the relay | Transformer |
---|---|
Product range | Sepam series 40 |
Device Name | T52 |
type of control and monitoring | Acknowledgement/lock ANSI code: 86 Logic selectivity ANSI code: 68 (option) Switching of groups of settings Warning ANSI code: 30 Contactor/circuit breaker control ANSI code: 94/69 Logic equation editor 100 operators |
type of counting | Phase current I1, I2, I3 RMS, residual current I0 Demand current I1, I2, I3, peak demand current IM1, IM2, IM3 Temperature (option) Voltage U21, U32, U13, V1, V2, V3, residual voltage V0 Frequency Positive sequence voltage Vd/rotation direction-negative sequence voltage Vi Active, reactive, apparent power P,Q,S-peak demand power PM, QM, power factor Calculated active and reactive energy (+/- Wh, +/- VAR.h) Active and reactive energy by pulse counting (+/- Wh, +/- VAR.h) (option) |
network and machine diagnostic type | Unbalance rate/negative sequence current Ii Recording of oscilloscopes Thermal capacity used Time remaining before overload tripping Waiting time after overload tripping Operating hours counter/running time Tripping context Phase shift |
Type of diagnostic cut-off organ | Cumulative breaking current Trip circuit supervision (option) Number of operations, operating time charging time (option) TC/TP supervision ANSI code: 60FL |
Type of measurement | Temperature Current Voltage Power factor Energy Frequency Power (P,Q) Peak demand power |
---|---|
type of protection | Thermal overload ANSI code: 49RMS (2) Thermostat / buchholz ANSI code: 26/63 (option) Neutral voltage displacement ANSI code: 59N (2) Circuit breaker failure ANSI code: 50BF (1) Undervoltage protection ANSI code: 27/27S (2) Overvoltage protection ANSI code: 59 (2) Directional earth fault ANSI code: 67N/67NC (2) Directional phase overcurrent ANSI code: 67 (2) Temperature monitoring (8 or 16 RTDs) ANSI code: 38/49T (option) Selective overcurrent logic ANSI code: CPLU 50/51 (4) Broken conductor ANSI code: 46BC (1) Phase overcurrent ANSI code: 50/51 (4) Earth fault / sensitive earth fault ANSI code: 50N/51N (4) Earth Fault/Sensitive Earth Fault ANSI code: 50G/51G (4) Negative Sequence/Unbalance ANSI code: 46 (2) Negative Sequence Overvoltage ANSI code: 47 (1) Over Frequency ANSI code: 81H (2) Under Frequency ANSI code: 81L (4) Cold Load Release I/O ANSI code: CPLU 50N/51N (4) |
communication protocol | Reading of measurements (option): Modbus Remote indication and fixing of event time (option): Modbus Remote commands (option): Modbus Remote protection setting (option): Modbus Transfer of disturbance recording data (option): Modbus |
max. input/output capacity | 10 inputs + 8 outputs |
Communication Compatibility | TCPIP Modbus Modbus RTU IEC 61850 IEC 60870-5-103 DNP3 |
user machine interface type | Without Remote Evolved |