Specifications
Relay application | Transformer |
---|---|
Range of product | Sepam series 80 Sepam series 80 NPP |
Device short name | T87 |
Control and monitoring type | Circuit breaker/contactor control ANSI code: 94/69 (option) Latching/acknowledgement ANSI code: 86 Logic discrimination ANSI code: 68 (option) Switching of groups of settings Annunciation ANSI code: 30 Automatic transfer (AT) (option) Logipam programming (ladder language) (option) Logic equation editor 200 operators |
Metering type | Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Measured residual current I’0 Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0 Negative sequence voltage Vi Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Apparent power S, S1, S2, S3 Peak demand power PM, QM Power factor Temperature (16 RTDs) (option) Phase current I’1, I’2, I’3 RMS Measured residual current I0, calculated I’0∑ Calculated residual current I’0∑ |
Network and machine diagnosis type | Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Tripping context Phase fault and earth fault trip counters Harmonic distortion (THD), current and voltage Ithd, Uthd Difference in amplitude, frequency and phase of voltages with synchro-check option Apparent positive sequence impedance Zd Apparent phase-to-phase impedances Z21, Z32, Z13 Differential current Idiff1, idiff2, Idiff3 Through current It1, It2, It3 Current phase displacement θ Phase displacement Datalog (DLG) |
Switchgear diagnosis type | Cumulative breaking current CT/VT supervision ANSI code: 60FL Trip circuit supervision ANSI code: 74 (option) Auxiliary power supply monitoring Nb of operations, operating time, charging time, nb of racking out operations (option) |
Type of measurement | Temperature Power factor Frequency Voltage Current Energy Peak demand power Harmonic distorsion (I THD & U THD) Power (P,Q) |
---|---|
Protection type | Thermostat / buchholz ANSI code: 26/63 (option) Neutral voltage displacement ANSI code: 59N (2) Breaker failure ANSI code: 50BF (1) Directional earth fault ANSI code: 67N/67NC (2) Directional phase overcurrent ANSI code: 67 (2) Synchro-check ANSI code: 25 (option) Overvoltage (L-L or L-N) ANSI code: 59 (4) Temperature monitoring (16 RTDs) ANSI code: 38/49T (option) Thermal overload for machines ANSI code: 49RMS (2) Restricted earth fault ANSI code: 64REF (2) Overfluxing (V/Hz) ANSI code: 24 (2) Two-winding transformer differential ANSI code: 87T (1) Negative sequence/unbalance ANSI code: 46 (2) Overfrequency ANSI code: 81H (2) Underfrequency ANSI code: 81L (4) Positive sequence undercurrent ANSI code: 27D (2) Remanent undervoltage ANSI code: 27R (2) Undervoltage (L-L or L-N) ANSI code: 27 (4) Negative sequence overvoltage ANSI code: 47 (2) Phase overcurrent ANSI code: 50/51 (8) Earth fault/sensitive earth fault ANSI code: 50N/51N (8) Earth fault/sensitive earth fault ANSI code: 50G/51G (8) Directional active overpower ANSI code: 32P (2) |
Communication port protocol | Measurement readout ( option ) : Modbus Remote indication and time tagging of events ( option ) : Modbus Remote control orders ( option ) : Modbus Remote protection setting ( option ) : Modbus Transfer of disturbance recording data ( option ) : Modbus |
Input output max capacity | 42 inputs + 23 outputs |
Communication compatibility | DNP3 IEC 61850 IEC 61850 goose message Modbus RTU Modbus TCPIP IEC 60870-5-103 |
User machine interface type | Remote Mimic-based Advanced Without |