Specifications
Relay application | Capacitor |
---|---|
Range of product | Sepam series 80 Sepam series 80 NPP |
Device short name | C86 |
Control and monitoring type | Circuit breaker/contactor control ANSI code: 94/69 (option) Latching/acknowledgement ANSI code: 86 Logic discrimination ANSI code: 68 (option) Switching of groups of settings Annunciation ANSI code: 30 Logipam programming (ladder language) (option) Logic equation editor 200 operators Capacitor step control (option) |
Metering type | Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0 Negative sequence voltage Vi Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Apparent power S, S1, S2, S3 Peak demand power PM, QM Power factor Temperature (16 RTDs) (option) Measured residual current I0, calculated I’0∑ |
Network and machine diagnosis type | Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Tripping context Phase fault and earth fault trip counters Harmonic distortion (THD), current and voltage Ithd, Uthd Apparent positive sequence impedance Zd Apparent phase-to-phase impedances Z21, Z32, Z13 Capacitor unbalance current and capacitance Phase displacement Datalog (DLG) |
Switchgear diagnosis type | Cumulative breaking current CT/VT supervision ANSI code: 60FL Trip circuit supervision ANSI code: 74 (option) Auxiliary power supply monitoring Nb of operations, operating time, charging time, nb of racking out operations (option) |
Type of measurement | Peak demand power Voltage Temperature Current Frequency Energy Power (P,Q) Power factor |
---|---|
Protection type | Neutral voltage displacement ANSI code: 59N (2) Breaker failure ANSI code: 50BF (1) Overvoltage (L-L or L-N) ANSI code: 59 (4) Temperature monitoring (16 RTDs) ANSI code: 38/49T (option) Thermal overload for capacitors ANSI code: 49RMS (2) Capacitor bank unbalance ANSI code: 51C (8) Negative sequence/unbalance ANSI code: 46 (2) Overfrequency ANSI code: 81H (2) Underfrequency ANSI code: 81L (4) Remanent undervoltage ANSI code: 27R (2) Negative sequence overvoltage ANSI code: 47 (2) Phase overcurrent ANSI code: 50/51 (8) Earth fault/sensitive earth fault ANSI code: 50N/51N (8) Earth fault/sensitive earth fault ANSI code: 50G/51G (8) Positive sequence undercurrent ANSI code: 27D (4) Undervoltage (L-L or L-N) ANSI code: 27 (2) |
Communication port protocol | Measurement readout ( option ) : Modbus Remote indication and time tagging of events ( option ) : Modbus Remote control orders ( option ) : Modbus Remote protection setting ( option ) : Modbus Transfer of disturbance recording data ( option ) : Modbus |
Input output max capacity | 42 inputs + 23 outputs |
Communication compatibility | DNP3 Modbus TCPIP IEC 61850 IEC 60870-5-103 IEC 61850 goose message Modbus RTU |
User machine interface type | Advanced Remote Without Mimic-based |