Specifications

Main
Relay application Capacitor
Range of product Sepam series 80
Sepam series 80 NPP
Device short name C86
Control and monitoring type Circuit breaker/contactor control ANSI code: 94/69 (option)
Latching/acknowledgement ANSI code: 86
Logic discrimination ANSI code: 68 (option)
Switching of groups of settings
Annunciation ANSI code: 30
Logipam programming (ladder language) (option)
Logic equation editor 200 operators
Capacitor step control (option)
Metering type Positive sequence voltage Vd/rotation direction
Frequency
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option)
Phase current I1, I2, I3 RMS
Demand current I1, I2, I3
Peak demand current IM1, IM2, IM3
Voltage U21, U32, U13, V1, V2, V3
Residual voltage V0
Negative sequence voltage Vi
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Peak demand power PM, QM
Power factor
Temperature (16 RTDs) (option)
Measured residual current I0, calculated I’0∑
Network and machine diagnosis type Unbalance ratio/negative sequence current Ii
Disturbance recording
Thermal capacity used
Remaining operating time before overload tripping
Waiting time after overload tripping
Running hours counter/operating time
Tripping context
Phase fault and earth fault trip counters
Harmonic distortion (THD), current and voltage Ithd, Uthd
Apparent positive sequence impedance Zd
Apparent phase-to-phase impedances Z21, Z32, Z13
Capacitor unbalance current and capacitance
Phase displacement
Datalog (DLG)
Switchgear diagnosis type Cumulative breaking current
CT/VT supervision ANSI code: 60FL
Trip circuit supervision ANSI code: 74 (option)
Auxiliary power supply monitoring
Nb of operations, operating time, charging time, nb of racking out operations (option)
Complementary
Type of measurement Peak demand power
Voltage
Temperature
Current
Frequency
Energy
Power (P,Q)
Power factor
Protection type Neutral voltage displacement ANSI code: 59N (2)
Breaker failure ANSI code: 50BF (1)
Overvoltage (L-L or L-N) ANSI code: 59 (4)
Temperature monitoring (16 RTDs) ANSI code: 38/49T (option)
Thermal overload for capacitors ANSI code: 49RMS (2)
Capacitor bank unbalance ANSI code: 51C (8)
Negative sequence/unbalance ANSI code: 46 (2)
Overfrequency ANSI code: 81H (2)
Underfrequency ANSI code: 81L (4)
Remanent undervoltage ANSI code: 27R (2)
Negative sequence overvoltage ANSI code: 47 (2)
Phase overcurrent ANSI code: 50/51 (8)
Earth fault/sensitive earth fault ANSI code: 50N/51N (8)
Earth fault/sensitive earth fault ANSI code: 50G/51G (8)
Positive sequence undercurrent ANSI code: 27D (4)
Undervoltage (L-L or L-N) ANSI code: 27 (2)
Communication port protocol Measurement readout ( option ) : Modbus
Remote indication and time tagging of events ( option ) : Modbus
Remote control orders ( option ) : Modbus
Remote protection setting ( option ) : Modbus
Transfer of disturbance recording data ( option ) : Modbus
Input output max capacity 42 inputs + 23 outputs
Communication compatibility DNP3
Modbus TCPIP
IEC 61850
IEC 60870-5-103
IEC 61850 goose message
Modbus RTU
User machine interface type Advanced
Remote
Without
Mimic-based