Specifications

 

Main
Using the relay Capacitor
Product range Sepam series 60
Device Name C60
type of control and monitoring Contactor/circuit breaker control ANSI code: 94/69 (option)
Acknowledgement/locking ANSI code: 86
Logic selectivity ANSI code: 68 (option)
Switching of groups of settings
Warning ANSI code: 30
Automatic transfer (AT) (option)
Editor of 200 logic operations
type of counting Positive sequence voltage Vd/direction of rotation
Frequency
Calculated active and reactive energy (+/- Wh, +/- VAR.h)
Active and reactive energy by pulse counting (+/- Wh, +/- VAR.h) (option)
Phase currents I1, I2, I3 RMS
Average current I1, I2, I3
Average peak current IM1, IM2, IM3
Voltage U21, U32, U13, V1, V2, V3
Residual voltage V0
Negative sequence voltage Vi
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Average peak power PM, QM
Power factor
Measured residual current I0, calculated I”0?
network and machine diagnostic type Unbalance rate/negative sequence current Ii
Oscilloscope recording
Used thermal capacity
Time remaining before overload tripping
Waiting time after overload tripping
Operating hours counter/running time
Tripping context
Phase fault and earth fault trip counters
Total harmonic distortion (THD), current and voltage Ithd, Uthd
Apparent positive sequence impedance Zd
Apparent impedances between phases Z21, Z32, Z13
Cable arcing fault detection
Phase displacement
Data log (DLG)
Type of diagnostic cut-off organ Cumulative breaking current
CT/TP supervision ANSI code: 60FL
Tripping circuit supervision ANSI code: 74 (option)
No. of operations, operating time, loading time, no. of unplugging operations (option)
Complementary
Type of measurement                             Power (P,Q)                                                                                                                  Frequency
Harmonic Distortion (I THD & U THD)
Current
Power Factor
Voltage
Peak Demand
Power Energy
type of protection Neutral Voltage Displacement ANSI Code: 59N (2)
Breaker Failure ANSI Code: 50BF (1)
Temperature Monitoring (16 RTDs) ANSI Code: 38/49T (option)
Phase Overcurrent ANSI Code: 50/51 (4)
Earth Fault/Sensitive Earth Fault ANSI Code: 50N/51N (4)
Earth Fault/Sensitive Earth Fault ANSI Code: 50G/51G (4)
Negative Sequence/Unbalance ANSI Code: 46 (2)
Over Frequency ANSI Code: 81H (2) Under
Frequency ANSI Code: 81L (4)
Positive Sequence Undercurrent ANSI Code: 27D (2)
Remaining Under Voltage ANSI Code: 27R (2)
Negative Sequence Over Voltage ANSI Code: 47 (2)
Under Voltage (LL or LN) ANSI Code: 27 (2)
Overvoltage (LL or LN) ANSI code: 59 (2)
Thermal overload for capacitors ANSI code: 49RMS (1)
communication protocol Reading of measurements (option): Modbus
Remote indication and fixing of event time (option): Modbus
Remote commands (option): Modbus
Remote protection setting (option): Modbus
Transfer of disturbance recording data (option): Modbus
max. input/output capacity 28 inputs + 16 outputs
Communication Compatibility DNP3
TCPIP Modbus
Modbus RTU
IEC 61850
IEC 60870-5-103
Message goose IEC 61850
user machine interface type Remote
Evolved
Dummy
Without