Specifications

Main
Range of Product PowerLogic P3
Product or Component Type Protection relay
Relay application Feeder
product reference P3G30-CBGAD-DA1FA-BBAAB
Mounting case size 30TE
Device mounting Flush
Mounting Mode Flush mounting
power supply 48…230 V AC/DC
measuring inputs 3 1/5 A CT phase current
1 5/1 A CT residual current
1 1/0.2 A CT residual current
4 100 V/110 V VT voltage
number of Digital Inputs (DI) 6
number of analogue inputs 0
number of Digital Outputs (DO) 10 DO
1 watchdog
number of analogue outputs 0
communication ports Front USB port 1
Rear RS485 1
Rear RJ45 1
communication protocols IEC 61850 ed. 1
IEC 61850 ed. 2
IEC 60870-5-101
DNP3 TCP
Modbus TCP
EtherNet/IP
IEC 60870-5-103
DNP3
Modbus RTU
DeviceNet
SPAbus
Cybersecurity Password protection
Port hardening
protection functions Underimpedance 21G
Overfluxing (V/Hz) 24
Synchro-check 25
Undervoltage 27
Positive sequence undervoltage 27P
Directional active underpower 32
Field loss (underimpedance) 40
Under reactance 21/40
Negative sequence overcurrent 46
Thermal overload protection 49
Earth fault overcurrent 50N/51N
Phase overcurrent 50/51
Breaker failure 50BF
Switch ON to fault (SOTF)
Breaker failure 50BF 8
Capacitor bank unbalance 51C
Voltage-restrained overcurrent 51V
Switch ON to fault (SOTF) 21G
Overvoltage 59
Earth fault overvoltage 59N
Stator earth fault 64S
Directional phase overcurrent 67
Directional earth fault 67N
Magnetising inrush detection 68F2
H5 detection 68H5
Pole slip 78PS
Underfrequency 81/81N
Rate of change of frequency 81R
Lockout relay 86
Programmable stages 99 8
Programmable curve
Cold load pick-up
CT supervision 60
VT supervision 60FL
Arc flash protection Yes
Relay Type Differential current relay
measurement functions Current 3-phase
Current zero sequence
Current positive sequence
Current negative sequence
Current ratio of negative and positive
Voltage phase to earth
Voltage phase to phase
Voltage zero sequence
Voltage positive sequence
Voltage negative sequence
Voltage ratio of negative and positive
Short circuit fault reactance
Fault location current
Earth fault reactance
Frequency
Active power
RMS active power
Reactive power
RMS reactive power
Apparent power
Reactive power zero sequence
RMS apparent power
Active energy
Reactive energy
Cos φ
RMS reactive power phase to earth
Tan φ
Power angle
Power factor
Voltage phasor diagram view
Current phasor diagram view
Current 2nd, 15th harmonics with THD
Apparent power phase to phase
Voltage 2nd, 15th harmonics with THD
Condition monitoring CB wear
Condition monitoring CB wear 2nd, 15th harmonics with THD
control functions Switchgear control and monitoring
Programmable switchgear interlocking
Local control on single-line diagram
Local control with I/O keys
Local/remote control
2 function keys
Mobile application with Easergy SmartApp
Web-server
Programmable logic
controllable switchgear devices 3 controlled + 3 displayed
number of setting groups 4
monitoring functions Trip circuit supervision 74
Circuit breaker monitoring
Relay self-monitoring
logs and records Event recording
Disturbance recording
Tripping context
Switchgear diagnosis type CT supervision TCS
Trip circuit supervision TCS
Connections – terminals Screw removable (digital input/output)
Pin removable (voltage transformer)
Ring lugs fixed (current transformer)
Complementary
Operating threshold 110…230 V AC/DC
Time synchronisation protocol SNTP
Software name ESetup Easergy Pro virtual simulation test
Easergy SmartApp
Web server Embedded HTTP server
Display type LCD 128 x 128 pixels with single line diagram
LCD 128 x 128 pixels with ANSI symbols
Number of key 2 customizable
Local signalling 2 LEDs
16 LEDs programmable
Height 6.9 in (176 mm)
Width 10.6 in (270 mm)
Depth 9.06 in (230 mm)
Net weight 9.3 lb(US) (4.2 kg) maximum