Specifications
Product range | PowerLogic P3 |
---|---|
Type of product or equipment | Protection relay |
Using the relay | Universal |
Product reference | P3U30-6AAA2BCAA |
Circuit breaker type | 30TE |
Food | 480 V AC/DC |
Measuring inputs | : TC 1/5 A PHASE CURRENT 3 : TC 1/5 A residual current 1 : TP 101 V/110 V voltage 4 |
Number of digital inputs (DI) | 16 |
number of analogue inputs | 0 |
Number of digital outputs (DO) | 1 guard dog 8 |
Number of analog outputs | 0 |
Communication ports | USB port 1 inside RJ45 2 rear panel |
Communication protocols | IEC 61850 ed. 1 IEC 61850 ed. 2 IEC 60870-5-101 DNP3 TCP Modbus TCP Ethernet IP |
Communication protocol | RSTP PTP |
Cybersecurity | Communication port hardening Password protection |
Protective functions | Phase overcurrent 50/51 Differential protection 67 Earth fault 50N/51N Directional earth fault 67N Transient intermittent 67NI Capacitor step unbalance 51C Broken conductor 46 I2/I1 Selective overcurrent logic Switch-on on fault (SOTF) Circuit breaker failure 50BF Directional active underpower 37P Fault location 21FL Recloser 79 Phase undercurrent 37 Long start, locked rotor 48/51LR Motor restart inhibition 66 Capacitor overvoltage 59C Negative sequence overcurrent 46 Negative sequence active power 67 Instruction sheet 32P Positive sequence undervoltage 27P Residual overvoltage 59N Underfrequency 81/81N Frequency derivative 81R Synchronism check 25 Interlock 86 CT supervision 60 Supervision TP 60 H2 detection 68H2 H5 detection 68H5 Negative sequence overcurrent 47 Programmable thresholds 99 Programmable curve |
Communication protocol | No |
Measuring functions | Three-phase current Zero sequence current Positive component current Negative component current Negative component current Ratio current between negative sequence and positive sequence Phase-to-earth voltage Phase-to-phase voltage Zero sequence voltage Positive component voltage Negative component voltage Ratio voltage between negative sequence and positive sequence Short-circuit fault reactance Fault current location Earth fault reactance Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Synoptic phase voltage Synoptic phase current Current 2nd, 15th harmonics with TDH Voltage 2nd, 15th harmonics with TDH Voltage interruption Monitoring of the status of the switching devices |
Control functions | Circuit breaker control and monitoring Programmable interlock Local control on vector diagram Local control with I/O keys Local/remote control 2 function keys Mobile application with EcoStruxureTM Power Device application Web server Programmable logic |
Controllable devices | 4 ordered + 8 displayed |
Number of setting groups | 4 |
Monitoring functions | Trip circuit supervision 74 Circuit breaker supervision Relay self-supervision |
Records and recordings | Event recording Recording of oscilloscopes Triggering context |
Type of diagnostic cut-off organ | TC/TP supervision ANSI code: 60 TC supervision Tripping circuit supervision ANSI code: TCS |
Connection mode | Removable screw (logic input/output) Removable eye lugs (current transformer) Removable pin (voltage transformer) |
Operating threshold | 110…230 V DC |
---|---|
Synchronization protocol | SNTP |
Software Name | ESetup Easergy Pro 2-source lock |
Web Server | Built-in HTTP server |
Display type | LCD 128 x 64 pixels with single-line synoptic |
Number of keys | 2 customizable |
Voltage indication | 4 LEDs 8 LEDs programmable |
Standards | IEC |
height | 169.5 mm |
Width | 170 mm |
Depth | 205 mm |
Weight | 2.5 kg minimum |