Specifications
Product range | PowerLogic P5 |
---|---|
Type of product or equipment | Protection and relay control |
Using the relay | Maximum directional phase current |
Product reference | P5F30-AACB-HABAH-BAEA |
Circuit breaker type | 30TE |
Mounting the device | Recessed |
Installation mode | Detachable |
Food | 48…250 V DC 100…230 V AC |
Measuring inputs | : TC 1/5 A PHASE CURRENT 3 : CSH residual current 1 : TP 101 V/110 V voltage 4 |
Number of sensors | 0 temperature sensor(s) 0 arc flash sensor(s) |
Number of digital inputs (DI) | 10 |
number of analogue inputs | 0 |
Number of digital outputs (DO) | 7 DO 1 guard dog |
Number of analog outputs | 0 |
Communication ports | RJ45 2 rear panel Expansion port 1 rear panel with backup memory USB port 2 front panel |
Communication protocols | IEC 61850 ed. 1 IEC 61850 ed. 2 DNP3 over ethernet Modbus TCP Ethernet IP |
Communication protocol | RSTP |
Cybersecurity | Communication port hardening Firmware signature Client IP address filter Secure communication with associated tools Security policy management Role-based access control LDAP security log RADIUS-based user authentication IEC 62443-4-2 SL1 |
Protective functions | Phase overcurrent 50/51 Directional phase overcurrent 67 Earth overcurrent 50N/51N Directional earth overcurrent 67N Transient intermittent 67NI Neutral admission 21YN Wattmetric earth fault 32N Capacitor step unbalance 51C Broken conductor 46 I2/I1 Current unbalance 46 I2/I1 Selective overcurrent logic Switching on fault (SOTF) H2 detection H5 detection Circuit breaker failure 50BF Directional active underpower 37P Fault location 21FL Recloser 79 Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Residual overvoltage 59N Underfrequency 81/81N Frequency derivative 81R Synchronism check 25 Locking 86 CT supervision 60 VT supervision 60 Thresholds programmable 99 Programmable logic Programmable curve |
Measuring functions | Three-phase current Zero sequence current Positive component current Negative component current Ratio of reverse to direct current Current and voltage diagram Current 2nd, 15th harmonics with TDH Three-phase voltage Residual voltage Zero sequence voltage Positive component voltage Negative component voltage Frequency |
Control functions | Circuit breaker control and monitoring Programmable interlock Local/remote control |
Controllable devices | 6 objects ordered + 2 objects monitored |
Number of setting groups | 4 |
Monitoring functions | Trip circuit supervision 74 Circuit breaker supervision Relay self-supervision |
Records and recordings | Event recording Recording of oscilloscope disturbances Triggering context Relay maintenance |
Type of diagnostic cut-off organ | TC/TP supervision ANSI code: 60 Trip circuit supervision ANSI code: 74 |
Connection mode | Screws (logic input/output) Ring terminals (analog inputs and outputs) |
Synchronization protocol | SNTP |
---|---|
Software Name | EcoStruxure Power Device ESetup Easergy Pro: virtual injection test |
Web Server | Built-in HTTP server |
Display type | 480 x 272 pixel color LCD |
Number of keys | 7 customizable |
Voltage indication | 4 x LED 10 x LED 3 colors programmable |
height | 176 mm |
Width | 152 mm |
Depth | 219 mm |
Weight | 3.5 kg |