Specifications
Range of product | PowerLogic P5 |
---|---|
Product or component type | Protection and control relay |
Relay application | Motor |
product reference | P5M30-AACB-GABAH-BAEA |
Mounting case size | 30TE |
Device mounting | Flush |
Mounting mode | Withdrawable |
power supply | 48…250 V DC 100…230 V AC |
measuring inputs | : 1/5 A CT phase current 3 : 1/5 A CT residual current 1 : 1 A CT residual current 1 : VT voltage 4 |
Number of sensors | 0 temperature sensor(s) 0 arc sensor(s) |
number of Digital Inputs (DI) | 10 |
number of analogue inputs | 0 |
number of Digital Outputs (DO) | 7 DO 1 watchdog |
number of analogue outputs | 0 |
communication ports | RJ45 2 rear Extension port 1 rear with backup memory USB port 2 front |
communication protocols | IEC 61850 ed. 1 IEC 61850 ed. 2 DNP3 over ethernet Modbus TCP EtherNet/IP |
Redundancy communication port protocol | RSTP |
Cybersecurity | Port hardening Firmware signature Client IP address filter Secured communication with assciated tools Security policy management Role-based access control Security log LDAP RADIUS based user authentication IEC 62443-4-2 SL1 |
protection functions | Phase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Restricted earth fault 64REF Directional earth fault 67N Transient earth fault 67NI Neutral admittance 21YN Earth fault wattmetric 32N Broken conductor 46 I2/I1 Current unbalance 46 I2/I1 Cold load pick-up Switch ON to fault (SOTF) H2 detection H5 detection Breaker failure 50BF Directional active underpower 37P Phase undercurrent 37 Excessive starting time, locked rotor 48/51LR Motor restart inhibition 66 Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Positive sequence undervoltage 27P Earth fault overvoltage 59N Underfrequency 81/81N Lockout relay 86 CT supervision 60 VT supervision 60 Programmable stages 99 Programmable logic Programmable curve |
measurement functions | Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Phasor diagram of currents or voltages Current 2nd, 15th harmonics with THD Voltage 3-phase Voltage residual Voltage zero sequence Voltage positive sequence Voltage negative sequence Frequency |
control functions | Switchgear control and monitoring Programmable switchgear interlocking Local/remote control |
controllable switchgear devices | 6 controlled + 2 monitored objects |
number of setting groups | 4 |
monitoring functions | Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring |
logs and records | Event recording Disturbance recording Tripping context Relay maintenance |
Switchgear diagnosis type | CT/VT supervision ANSI code: 60 Trip circuit supervision ANSI code: 74 |
Connections – terminals | Screw (digital input/output) Ring lugs (analog inputs and outputs) |
Time synchronisation protocol | SNTP |
---|---|
Software name | EcoStruxure Power Device ESetup Easergy Pro: virtual simulation test |
Web server | Embedded HTTP server |
Display type | Colour LCD 480 x 272 pixels |
Number of key | 7 customizable |
Local signalling | 4 x LED 10 x LED tri-colour programmable |
Height | 176 mm |
Width | 152 mm |
Depth | 219 mm |
Net weight | 3.5 kg |