Specifications
Product range | PowerLogic P5 |
---|---|
Type of product or equipment | Protection and relay control |
Using the relay | Engine |
Product reference | P5M30-AACB-GAAAA-BAEA |
Circuit breaker type | 30TE |
Mounting the device | Recessed |
Installation mode | Detachable |
Food | 48…250 V DC 100…230 V AC |
Measuring inputs | : TC 1/5 A PHASE CURRENT 3 : TC 1/5 A residual current 1 : TC 1 A residual current 1 : TP 101 V/110 V voltage 4 |
Number of sensors | 0 temperature sensor(s) 0 arc flash sensor(s) |
Number of digital inputs (DI) | 10 |
number of analogue inputs | 0 |
Number of digital outputs (DO) | 7 DO 1 guard dog |
Number of analog outputs | 0 |
Communication ports | Front USB port 2 |
Communication protocols | – |
Cybersecurity | Communication port hardening Firmware signature Client IP address filter Secure communication with associated tools Security policy management Role-based access control LDAP security log RADIUS-based user authentication IEC 62443-4-2 SL1 |
Protective functions | Phase overcurrent 50/51 Directional phase overcurrent 67 Earth overcurrent 50N/51N Restricted earth fault 64REF Directional earth overcurrent 67N Transient intermittent 67NI Neutral admission 21YN Wattmetric earth fault 32N Broken conductor 46 I2/I1 Current unbalance 46 I2/I1 Selective overcurrent logic Fault triggering (SOTF) H2 detection H5 detection Circuit breaker failure 50BF Directional active underpower 37P Phase undercurrent 37 Excessively long start, rotor lock 48/51LR Motor restart inhibition 66 Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Positive sequence undervoltage 27P Residual maximum voltage 59N Underfrequency 81/81N Locking 86 CT supervision 60 VT supervision 60 Programmable thresholds 99 Programmable logic Programmable curve |
Measuring functions | Three-phase current Zero sequence current Positive component current Negative component current Ratio of reverse to direct current Current and voltage diagram Current 2nd, 15th harmonics with TDH Three-phase voltage Residual voltage Zero sequence voltage Positive component voltage Negative component voltage Frequency |
Control functions | Circuit breaker control and monitoring Programmable interlock Local/remote control |
Controllable devices | 6 objects ordered + 2 objects monitored |
Number of setting groups | 4 |
Monitoring functions | Trip circuit supervision 74 Circuit breaker supervision Relay self-supervision |
Records and recordings | Event recording Recording of oscilloscope disturbances Triggering context Relay maintenance |
Type of diagnostic cut-off organ | TC/TP supervision ANSI code: 60 Trip circuit supervision ANSI code: 74 |
Connection mode | Screws (logic input/output) Ring terminals (analog inputs and outputs) |
Software Name | ESetup Easergy Pro: Virtual Injection Test |
---|---|
Display type | 480 x 272 pixel color LCD |
Number of keys | 7 customizable |
Voltage indication | 4 x LED 10 x LED 3 colors programmable |
height | 176 mm |
Width | 152 mm |
Depth | 219 mm |
Weight | 3.5 kg |