Specifications
Range of product | PowerLogic P5 |
---|---|
Product or component type | Protection and control relay |
Relay application | Feeder – directional over current |
product reference | P5F30-BACB-IAAAA-BAEA |
Mounting case size | 30TE |
Device mounting | Flush |
Mounting mode | Withdrawable |
power supply | 48…250 V DC 100…230 V AC |
measuring inputs | : LPCT phase current 3 : CSH residual current 1 : LPVT voltage 4 |
Number of sensors | 0 temperature sensor(s) 0 arc sensor(s) |
number of Digital Inputs (DI) | 16 |
number of analogue inputs | 0 |
number of Digital Outputs (DO) | 11 DO 1 watchdog |
number of analogue outputs | 0 |
communication ports | USB port 2 front |
communication protocols | – |
Cybersecurity | Port hardening Firmware signature Client IP address filter Secured communication with assciated tools Security policy management Role-based access control Security log LDAP RADIUS based user authentication IEC 62443-4-2 SL1 |
protection functions | Phase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Directional earth fault 67N Transient earth fault 67NI Neutral admittance 21YN Earth fault wattmetric 32N Capacitor bank unbalance 51C Broken conductor 46 I2/I1 Current unbalance 46 I2/I1 Cold load pick-up Switch ON to fault (SOTF) H2 detection H5 detection Breaker failure 50BF Directional active underpower 37P Fault locator 21FL Recloser 79 Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Earth fault overvoltage 59N Underfrequency 81/81N Rate of change of frequency 81R Synchro-check 25 Lockout relay 86 CT supervision 60 VT supervision 60 Programmable stages 99 Programmable logic Programmable curve |
measurement functions | Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Phasor diagram of currents or voltages Current 2nd, 15th harmonics with THD Voltage 3-phase Voltage residual Voltage zero sequence Voltage positive sequence Voltage negative sequence Frequency |
control functions | Switchgear control and monitoring Programmable switchgear interlocking Local/remote control |
controllable switchgear devices | 6 controlled + 2 monitored objects |
number of setting groups | 4 |
monitoring functions | Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring |
logs and records | Event recording Disturbance recording Tripping context Relay maintenance |
Switchgear diagnosis type | CT/VT supervision ANSI code: 60 Trip circuit supervision ANSI code: 74 |
Connections – terminals | Screw (digital input/output) Ring lugs (analog inputs and outputs) |
Software name | ESetup Easergy Pro: virtual simulation test |
---|---|
Display type | Colour LCD 480 x 272 pixels |
Number of key | 7 customizable |
Local signalling | 4 x LED 10 x LED tri-colour programmable |
Height | 176 mm |
Width | 152 mm |
Depth | 219 mm |
Net weight | 3.5 kg |
Reviews
There are no reviews yet.